DOC 6511_Release K
ATS-6511A/B/C Users Guide
23
3
Operations
The ATS-6511 is used to extend the timing signals provided by the ATS-6501 over fiber optic
cabling to accommodate transmission over long distance and improve signal integrity.
3.1 Front Panel
The ATS-6511 has several front panel indicators to provide the operator with the overall status of
the unit and will provide a visual alarm indication if a problem with the hardware or the unit
detects a condition that would cause the output signals to be outside of their timing specifications.
More detailed status information can be retrieved using the
status
command on the Command
Port.
Figure
5
ATS-6511 Front Panel
3.1.1 Power Supply Indicators
Each power supply has a front panel indicator that provides the operator an instant visual
indication of the supply status. Power Supply #1 is on the left, power supply #2 is on the right as
viewed from the front.
Indicator
Status
Off
No power is being provided to the ATS-6511.
Green
Power supply is good and is supplying power.
Red
ATS-6511 has power and the module has failed, is not seated properly, or is
unplugged from the power source.
Table 1
Power Supply Indicator
3.1.2 Alarm Indicator
The Alarm LED will turn red when the unit is not producing timing within their specifications or
the system has suffered a major hardware failure.
Indicator
Status
Off
Unit has no current alarms.
Green
This indicator should only turn green during the front panel POST.
Red
Either power supply is missing/has failed or is without input power.
Any output module(s) is reporting a failure
Outputs are not enabled (Power Up).
Reference clock wander exceeded 100ns from fiber 1 PPS or input reference(s)
are not present.
The outputs are not locked to the reference input.
Over temperature (internal temperature is greater than 65 C)
Table 2 Alarm Indicator
Summary of Contents for ATS-6511A