Introduction
CWS
−
D100
−
B Welding System
2005 Swagelok Company, all rights reserved
September 2005
1-12
Table 1-9
Adapter Inserts for CWS-5FSP1
Model
Used for
Comments
CWS-5MBVCO-04
316L-4-BVCO-1
316L-4-VCO-1-4TB2
1/4 in. VCR
weld glands
glands must have
overall length of
1.12 in. (28 mm)
or less with
captured male
nut SS-4-SVCR-4
CWS-5FVCR-04
1/4 in. VCR
weld glands
glands must have
overall length of
0.72 in. (18 mm)
or less with
captured female
nut SS-4-VCR-1
CWS-5FBVCO-04
316L-4-BVCO-3
1/4 in. VCR
weld glands
glands must have
overall length of
0.77 in. (20 mm)
or less with
captured female
nut SS-4-VCR-1
CWS-5MSVCR-04
6LV-4-SVCR-3
with captured male
nut SS-4-SVCR-4
CWS-5FSVCR-04
6LV-4-SVCR-3S
6LV-4-SVCR-3
with captured female
nut SS-4-SVCR-1
Table 1-10 Extension Cords
Model
Supply Voltage
Wire gauge
0 ft to 50 ft
(0 m to 15 m)
Wire gauge
50 ft to 100 ft
(15 m to 30 m)
CWS-D100-1B
115 V (ac)
#12 AWG
(2,5 mm)
#10 AWG
(4,0 mm)
CWS-D100-2B
230 V (ac)
#12 AWG
(2,5 mm)
#10 AWG
(4,0 mm)
Some power loss will occur, depending on the length of the extension
cord. See Table 1-10 to determine the
minimum
wire size to use.
WARNING!
DO NOT USE EXTENSION
CORDS THAT ARE IN POOR
PHYSICAL CONDITION OR
HAVE INSUFFICIENT
CURRENT CAPACITY.
FAILURE TO DO SO
CAN POSE FIRE AND
SHOCK HAZARDS.