Weld Parameter Adjustment
CWS
−
D100
−
B Welding System
Swagelok Company, All rights reserved
September 2005
5-22
Impulse Rate Reference Weld
Table 5-16 lists the parameter used to create the reference
weld shown in Figure 5-17.
Table 5-16 Impulse Rate Reference Weld
Parameter
Reference
Setting
This
Setting
Impulse Rate
10
10
Impulse Rate Weld Example No. 1
Table 5-17 lists the parameter change used to create the
weld shown in Figure 5-18.
Table 5-17 Weld Example No. 1
Parameter
Reference
Setting
This
Setting
Impulse Rate
10
05
Lowering the frequency reduces weld-spot overlap.
Impulse Rate Weld Example No. 2
Table 5-18 lists the parameter change used to create the
weld shown in Figure 5-19.
Table 5-18 Weld Example No. 2
Parameter
Reference
Setting
This
Setting
Impulse Rate
10
25
Raising the frequency increases weld-spot overlap.
Adjusting Controls for
Weld Quality
At times, the welding parameters (as described on
page 5-9) must be adjusted to create an acceptable weld.
Use the flow chart in Figure 5-20 to assist in adjusting the
weld parameters.
Figure 5-17 Impulse Rate
Reference Weld
Figure 5-18 Impulse Rate Weld
Example No. 1
Figure 5-19 Impulse Rate Weld
Example No. 2