CWS
−
D100
−
B Welding System
Weld Parameter Adjustment
2005 Swagelok Company, all rights reserved
September 2005
5-21
Weld Example No. 7
Table 5-14 lists the parameter change used to create the
weld shown in Figure 5-15.
Table 5-14 Weld Example No. 7
Parameter
Reference
Setting
This
Setting
Speed (s/rev)
26 (19)
33 (15)
Raising the Rotor Speed decreases the heat input per unit of
electrode travel resulting in no inside diameter penetration.
Weld Example No. 8
Table 5-15 lists the parameter change used to create the
weld shown in Figure 5-16.
Table 5-15 Weld Example No. 8
Parameter
Reference
Setting
This
Setting
Speed (s/rev)
26 (19)
19 (26)
Lowering the Rotor Speed increases the heat input per unit
of electrode travel resulting in increased inside diameter
dropthrough and weld bead width.
Figure 5-15 Weld Example No. 7
Figure 5-16 Weld Example No. 8
Reference Weld Illustration