43
Connection of temperature and
irradiation sensor
The optional addition of an irradiation
sensor (model Si-01TC-K from Ingenieur-
büro Mencke & Tegtmeyer) with an
integrated PT-100 temperature sensor for
temperature measurement enables the
acquisition of irradiation data and the
corresponding module temperature and
storage in the internal data memory as
a 5-minute mean value. This additional
measuring unit helps analyse the system
output. Based on the values, any errors
on the PV generator, e.g. shading or fail-
ure of solar cells, can be detected.
Temperature/irradiation sensor
Assignment of sensor connection
Pin assignment
of plug sensor
Connection designation
of sensor
Connection designation
of solar inverter
Pin 1
Positive-signal irradiation strength
Solar
Pin 2
Positive-signal temperature
Temp
Pin 3
Reference earth
V-
Pin 4
Positive connection 5V
V+