81
Malfunction
Description
Remedies
208:UAC3<Min
Your solar inverter is equipped
with a three-phase voltage
monitoring function according
to DIN VDE 0126-1-1. It con-
stantly monitors the voltage
level of the individual phases
(here: L3). When the minimum
permissible limit is dropped
below, the solar inverter stops
feeding and does not start up
again until the voltage value
exceeds the minimum permis-
sible limit.
➡
Ask your Electric Utility
about grid stability and de-
sign.
209:Isol.op.
You solar inverter is equipped
with a high-quality redundant
grid monitoring function ac-
cording to DIN VDE 0126-1-1
and constantly monitors the
grid. If one of the phases fails,
or if the phase position be-
tween the individual conduc-
tors changes, the solar inverter
stops feeding and does not
start up again until the error is
eliminated.
➡
Check the phases L2 and L3.
➡
Ask your Electric Utility
about grid stability and de-
sign.
81
Malfunction
Description
Remedies
210:Frq1>Max
The solar inverter continually
monitors the grid frequency of
the phase feeding in. If this lies
above the permissible value,
the solar inverter stops feeding
and does not start up again un-
til the value is below the limit.
➡
Ask your Electric Utility
about grid stability and de-
sign.
211:Frq1<Min
The solar inverter continually
monitors the grid frequency of
the phase feeding in. If this lies
below the permissible value,
the solar inverter stops feeding
and does not start up again un-
til the value is above the limit.
➡
Ask your Electric Utility
about grid stability and de-
sign.
Summary of Contents for AT 2700
Page 1: ...User Manual for Sunways Solar Inverter AT 5000 AT 4500 AT 3600 AT 2700...
Page 8: ...1 0 Product Description...
Page 16: ...16 2 0 Safety precautions...
Page 22: ...22 3 0 Installation...
Page 46: ...46 4 0 Commissioning...
Page 56: ...56 5 0 Operation...
Page 96: ...96 6 0 System monitoring...
Page 129: ...129...
Page 130: ...130 7 0 Appendix...
Page 135: ...135 Efficiency of AT 5000 Output power W...
Page 136: ...136 Efficiency of AT 4500 Output power W...
Page 137: ...137 Efficiency of AT 3600 Output power W...
Page 138: ...138 Efficiency of AT 2700 Output power W...
Page 140: ......
Page 141: ...C F Werbung und Dokumentation Villingen Schwenningen www cundf de...