Model
AT 5000
AT 4500
AT 3600
AT 2700
Insulation, frequency and DC cur-
rent monitoring
integrated according to DIN VDE 0126-1-1
Required phases, number of grid
connections
3 (L1, L2, L3, N, PE)
Number of feed-in phases (230 V
single-phase)
1
Performance
Stand-by consumption
6,5 W
Night-time consumption
< 0,06 W
Maximum efficiency
95,5%
95,5%
95,5%
95,5%
European efficiency
95,0%
95,0%
94,9%
94,7%
MPP efficiency (static)
99,99%
99,99%
99,99%
99,99%
Switching concept
HERIC® / FP topology, transformerless
Other
DC switch
internal, mechanical
Grid-connection fuse layout
25 A
25 A
25 A
16 A
Data interfaces
Ethernet, CAN, RS485, voltageless alarm relay, S0
pulse output, modem
Sensor interfaces
irradiation, temperature
LCD, backlit, 128 x 64 pixels
Display
Plant supervision
active alarm via e-mail, integrated web-server, Sun-
ways Communictor, Sunways Portal
IP degree of protection accord-
ing to IEC 60529
IP 54
Model
AT 5000
AT 4500
AT 3600
AT 2700
Max. relative humidity
95%
Cooling
free convection
Ambient temperature
-25°C...40°C (at full load)
Overload behaviour
working point adjustment
Dimensions (height x width x depth)
59 x 35 x 21 cm
Weight
29 kg
Type of installation
wall installation
Noise development
< 35 dB (A)
Standard warranty (option)
5 years (10 years)
Certificates
CE, DIN VDE 0126-1-1
133
Summary of Contents for AT 2700
Page 1: ...User Manual for Sunways Solar Inverter AT 5000 AT 4500 AT 3600 AT 2700...
Page 8: ...1 0 Product Description...
Page 16: ...16 2 0 Safety precautions...
Page 22: ...22 3 0 Installation...
Page 46: ...46 4 0 Commissioning...
Page 56: ...56 5 0 Operation...
Page 96: ...96 6 0 System monitoring...
Page 129: ...129...
Page 130: ...130 7 0 Appendix...
Page 135: ...135 Efficiency of AT 5000 Output power W...
Page 136: ...136 Efficiency of AT 4500 Output power W...
Page 137: ...137 Efficiency of AT 3600 Output power W...
Page 138: ...138 Efficiency of AT 2700 Output power W...
Page 140: ......
Page 141: ...C F Werbung und Dokumentation Villingen Schwenningen www cundf de...