![Sunways AT 2700 User Manual Download Page 131](http://html1.mh-extra.com/html/sunways/at-2700/at-2700_user-manual_1401168131.webp)
131
7.1 Technical data
Model
AT 5000
AT 4500
AT 3600
AT 2700
DC Input
Rated DC power
5200 W
4700 W
3750 W
2800 W
Maximum DC current
22,0 A
22,0 A
15,5 A
15,5 A
Nominal DC voltage
350 V
MPP voltage range
236...600 V 214...600 V 242...600 V 181...600 V
Maximum voltage DC
680 V
Number of inputs per MPP
tracker
2 x Tyco Solarlok
Number of MPP trackers
1
AC output
Rated AC output power
5000 W
4500 W
3600 W
2700 W
Maximum AC power
5000 W
4500 W
3600 W
2700 W
Nominal AC current
21,7 A
19,6 A
15,7 A
11,7 A
Maximum AC current
23,0 A
21,0 A
17,0 A
12,5 A
Nominal frequency
50 Hz
Frequency tolerance range
47,5...50,2 Hz (according to DIN VDE 0126-1-1)
Grid voltage
230 V
AC voltage range
-20%...+15% (according to DIN VDE 0126-1-1)
Distortion factor at Pn
< 4%
Reactive power factor (cos phi)
ca. 1
Grid voltage monitoring
according to DIN VDE 0126-1-1
Earth fault protection
RCD (according to DIN VDE 0126-1-1)
Summary of Contents for AT 2700
Page 1: ...User Manual for Sunways Solar Inverter AT 5000 AT 4500 AT 3600 AT 2700...
Page 8: ...1 0 Product Description...
Page 16: ...16 2 0 Safety precautions...
Page 22: ...22 3 0 Installation...
Page 46: ...46 4 0 Commissioning...
Page 56: ...56 5 0 Operation...
Page 96: ...96 6 0 System monitoring...
Page 129: ...129...
Page 130: ...130 7 0 Appendix...
Page 135: ...135 Efficiency of AT 5000 Output power W...
Page 136: ...136 Efficiency of AT 4500 Output power W...
Page 137: ...137 Efficiency of AT 3600 Output power W...
Page 138: ...138 Efficiency of AT 2700 Output power W...
Page 140: ......
Page 141: ...C F Werbung und Dokumentation Villingen Schwenningen www cundf de...