85
Malfunction
Description
Remedies
303:Overtmp.
Your solar inverter is designed
for an ambient temperature of
up to +40°C. When a specified
temperature threshold of the
heat sink is reached, the output
power is reduced linearly.
Should the heat sink tempera-
ture nevertheless continue to
increase, feeding is stopped.
After the heat sink tempera-
ture drops, the solar inverter
starts up again automatically.
The maximum permissible
ambient temperature has been
exceeded.
➡
The installation location
is not suitable. Please find
another installation location.
The necessary air circulation
was not taken into account
during installation.
➡
Clean the solar inverter, if
dirt prevents cooling.
➡
Observe the installation
distances specified in the
manual.
Objects were laid on the heat
sink and unimpaired convec-
tion was prevented.
➡
Remove the objects.
Malfunction
Description
Remedies
304:Mains rel.
The AT solar inverter checks the
operation of the mains relay
prior to every switch-on. An
error was detected during this
check.
➡
Restart the solar inverter.
If the error still occurs, please
contact the technical hotline.
The phone number is provided
on the back of the manual.
305:AFI Test
The AT solar inverter checks the
operation of its residual-cur-
rent monitoring unit prior to
every switch-on. An error was
detected during this check.
➡
Restart the solar inverter.
If the error still occurs, please
contact the technical hotline.
The phone number is provided
on the back of the manual.
85
Summary of Contents for AT 2700
Page 1: ...User Manual for Sunways Solar Inverter AT 5000 AT 4500 AT 3600 AT 2700...
Page 8: ...1 0 Product Description...
Page 16: ...16 2 0 Safety precautions...
Page 22: ...22 3 0 Installation...
Page 46: ...46 4 0 Commissioning...
Page 56: ...56 5 0 Operation...
Page 96: ...96 6 0 System monitoring...
Page 129: ...129...
Page 130: ...130 7 0 Appendix...
Page 135: ...135 Efficiency of AT 5000 Output power W...
Page 136: ...136 Efficiency of AT 4500 Output power W...
Page 137: ...137 Efficiency of AT 3600 Output power W...
Page 138: ...138 Efficiency of AT 2700 Output power W...
Page 140: ......
Page 141: ...C F Werbung und Dokumentation Villingen Schwenningen www cundf de...