Malfunction
Description
Remedies
406:Solar
(Warning)
No sensor found on sensor
channel 1 (solar).
If you have connected a sensor:
➡
Check the connection to
your sensor.
If you have not connected a
sensor:
➡
Check the configuration
with the Sunways Browser.
407:Temp.
(Warning)
No sensor found on sensor
channel 2 (temperature).
If you have connected a sensor:
➡
Check the connection to
your sensor.
If you have not connected a
sensor:
➡
Check the configuration
with the Sunways Browser.
90
Malfunction
Description
Remedies
408:CAN Comm
(Warning)
Communication malfunctions
occur repeatedly on the CAN
bus.
A malfunction occurs in the
data transmission on the CAN
bus.
However, a data exchange con-
tinues to be possible.
➡
Check whether all connec-
tors of the bus lines and the
terminating resistors are
properly mounted.
➡
Check whether the bus lines
have been routed parallel to
power cables. Separate bus
lines and power cable from
each other spatially if neces-
sary.
409:CAN Conf.
(Warning)
CAN bus is in the configuration
mode. No measured values are
transferred.
At least one unit is in the menu
item «Settings – Network
– CAN bus».
➡
Close this menu for all units.
Summary of Contents for AT 2700
Page 1: ...User Manual for Sunways Solar Inverter AT 5000 AT 4500 AT 3600 AT 2700...
Page 8: ...1 0 Product Description...
Page 16: ...16 2 0 Safety precautions...
Page 22: ...22 3 0 Installation...
Page 46: ...46 4 0 Commissioning...
Page 56: ...56 5 0 Operation...
Page 96: ...96 6 0 System monitoring...
Page 129: ...129...
Page 130: ...130 7 0 Appendix...
Page 135: ...135 Efficiency of AT 5000 Output power W...
Page 136: ...136 Efficiency of AT 4500 Output power W...
Page 137: ...137 Efficiency of AT 3600 Output power W...
Page 138: ...138 Efficiency of AT 2700 Output power W...
Page 140: ......
Page 141: ...C F Werbung und Dokumentation Villingen Schwenningen www cundf de...