Global 400 User Manual
66 of 85
v1.1 revision 1
Chapter 7: EtherNet/IPTM
2 February 2016
tightening.
17
Set
2
Angle Max
UDINT
Maximum angle for a valid
tightening.
Reserved for future use
18
Set
2
Head Length
REAL
Length of the head in mm.
19
Set
2
Autoclear time
USINT
Minimum amount of
seconds a torque must be
steady before it is reported.
Measured in 0.1s.
1
Only available for parameters using tools of type 2 (click wrench)
2
Only available for parameters using tools of type 3 (digital torque wrench)
Services
Service
Code
Available in
Service Name
Description of Service
Class
Instance
0x05
No
Yes
Reset
Resets the parameter to factory defaults.
0x0E
Yes
Yes
Get_Attribute_Single Returns the contents of the specified attribute.
0x10
No
Yes
Set_Attribute_Single
Modifies a single attribute.