Chapter 3: Configuring the unit
2 February 2016
Capacity
This field indicates the maximum torque the tool can withstand in ft-lb as reported by the tool.
This field is only listed for digital tools and cannot be edited.
Air code
This field indicates which type of air tool is attached to the transducer.
This field is only listed for air tools.
Forgetting Tools
Each tool can only be associated with a single qualifier at a time, but learning a tool to another
qualifier does not automatically remove it from the previous qualifier. If you have changed or
are planning to change a tool from a Global 400 to another qualifier, you should have the
qualifier “forget” the tool. To do so, press
Forget
on the Tool Edit screen to remove the tool
from the qualifier. This will cause the qualifier to no longer respond to the tool and will make
any parameters using the tool and any groups or jobs using those parameters invalid.
Parameters
Selecting Parameters
Figure 25: Main menu - Parameters
Figure 26: Choose Parameter screen
Function keys
1.
SELECT – Select the currently highlighted parameter to run. Only available for selectable
parameters.
2.
EDIT – Edit the currently highlighted parameter.
3.
COPY – Selects the currently highlighted parameter to be copied to another location.
4.
RETURN [ESC] – Returns to the main menu.
The Choose Parameter screen shows all the parameters in the unit in a 10x10 grid. Only the
parameters with tools assigned will show their numbers on the grid. A selectable parameter will
have a black number. A defined, but not selectable, parameter will be shown in red. A
parameter is defined when a tool number is assigned to it. If the assigned tool number is an
empty tool slot, because either no tool was ever learned or the previous tool was forgotten, the
parameter will become unselectable.