![Sturtevant Richmont Global 400 User Manual Download Page 65](http://html1.mh-extra.com/html/sturtevant-richmont/global-400/global-400_user-manual_1387402065.webp)
Global 400 User Manual
65 of 85
v1.1 revision 1
Chapter 7: EtherNet/IPTM
2 February 2016
C.E. Parameter Object
Class Code: 65 Hex
The C.E. Parameter Object refers to a parameter that describes the required operation for a batch
of tightenings. This should not be confused with the Parameter Object (class code 10 hex)
defined in the open portion of the Ethernet/IP
TM
protocol, which has a different use and is not
implemented in this product line.
Class Attributes
ID
Access
Name
Data Type
Description of Attribute
Semantics of Value
1
Get
Revision
UINT
Revision of this object
1
2
Get
Max Instance
UINT
Maximum instance number
of a parameter set object in
the device.
The maximum number of
parameters as specified
for the product.
Instance Attributes
ID
Access
Name
Data Type
Description of Attribute
Semantics of Value
1
Set
Name
SHORT_STRING Name of the parameter
displayed on screen and
reported in results
Maximum length is 25
characters
2
Get
Last Modified
DT
Last time the parameter
attributes were modified
3
Set
Tool
UINT
Instance number of tool
used for this parameter
4
Set
Holding Tool
UINT
Instance number of holding
tool used for this parameter
5
Set
Batch
USINT
Batch size
6
Get
Number of
Batches
UINT
Number of batches run in
this parameter
This value resets on
powerup.
7
Set
1
Timer Min
ITIME
Minimum hold time for a
valid click.
Range T#0s000ms –
2s550ms
8
Set
1
Timer Max
ITIME
Maximum hold time for a
valid click
Range T#0s000ms –
2s550ms
9
Set
1
Time Between
Cycles
UDINT
Minimum amount of time
required between results
Range T#0s000ms –
65s536ms
10
Set
1
Time Between
Batches
UDINT
Minimum amount of time
required between the last
result of a batch and the first
result of the next batch
Range T#0s000ms –
65s536ms
11
Set
2
Torque Unit
ENGUNIT
Unit of measurement for
toruqes
12
Set
2
Torque Min
REAL
Minimum torque for a valid
tightening.
13
Set
2
Torque Max
REAL
Maximum torque for a valid
tightening.
14
Set
2
Torque Direction USINT
Allowed torque direction for
a valid tightening.
One of:
0 = positive
1 = negative
2 = both
15
Set
2
Torque Mode
USINT
Mode used to measure
torque.
One of:
0 = peak
1 = residual
16
Set
2
Angle Min
UDINT
Minimum angle for a valid
Reserved for future use