Result timeout
Default: 5 seconds
Range: 0 to 60 seconds
This setting controls how long the qualifier will wait for a response from the ToolsNet server
when sending a tightening or keep alive packet. If no response is received within the specified
result timeout, the qualifier will try again, up to the specified number of retries. If no response is
received after all retries, the ToolsNet connection is considered broken and will have to be re-
established.
Result retries
Default: 2
Range: 0 to 10
This setting controls how many times the qualifier will resend a tightening or keep alive packet
to the ToolsNet server before considering the connection broken. If no response is received
within the specified result timeout, the qualifier will try again, up to the specified number of
retries. If no response is received after all retries, the ToolsNet connection is considered broken
and will have to be re-established.
Keep alive
Default: 30 seconds
Range: 0 to 3600 seconds
This setting controls how often the qualifier will send a keep alive packet to the ToolsNet server
if no other packets are being sent. When set to 0, the qualifier does not send keep alive packets.
This value is recommended to be less than half the inactivity timeout of the server to ensure the
connection is not closed due to a single missed keep alive packet. For example, if the server is
configured to timeout after 30 seconds of inactivity, the keep alive setting on the unit should be
less than 15 seconds.
System number
Default: 1
Range: 0 to 9999
This setting controls the system number the qualifier reports to the ToolsNet server in
identification and tightening packets.
Station number
Default: 1
Range: 0 to 9999
This setting controls the station number the qualifier reports to the ToolsNet server in
identification and tightening packets.