Operation
4
Auxiliary equipment
In these cases, the sensitivity and the range of
the ceiling sensor system must be adjusted.
For more information, refer to the next chapter.
Changing the sensor settings
The ceiling sensor system is supplied by
STILL with the following factory settings:
Sensitivity: High
Ceiling height: 24 m
– Pull out the connecting cable from the
sensor.
1
– On the underside of the assembly baseplate
on the overhead guard, loosen the four nuts
(1) on the sensor.
– Carefully remove the sensor.
2
– Using the supplied key (2), open the sensor
housing to gain access to the DIP switches.
57348011850 EN - 02/2019 - 11