5
Maintenance
Maintenance every 1000 hours
Hydraulic systems
Checking the oil level
To check the hydraulic oil level:
– Lower the load arms completely.
– Pull the emergency off switch.
– Remove the front hood.
– The oil level (7) must be between the min.
and max. on the tank for the truck functions
to operate correctly.
– Top up if necessary after unscrewing the
plug (8).
– Refit and tighten the plug afterwards.
CAUTION
Deterioration or destruction of the equipment
Only use hydraulic oil that complies with the specifi-
cations (see recommended lubricants).
Checking the system for leaks
– Inspect the hydraulic system:
• Pipes
• Hoses and connections between the pump
unit and the cylinders
– Tighten the connections if necessary.
– Check that the hoses are attached correctly
and show no signs of friction wear.
If you find a leak, please contact our service
engineers.
Cleaning the breather plug on the
hydraulic tank
– Lower the lifting mechanism.
– Unscrew the plug.
– Clean the strainer in the breather plug with
compressed air.
110
1170 801 15 09 [EN]
Summary of Contents for EXG-10
Page 2: ......
Page 7: ...1 Introduction ...
Page 20: ...1 Introduction Environmental considerations 14 1170 801 15 09 EN ...
Page 21: ...2 Safety ...
Page 31: ...3 Overviews ...
Page 39: ...4 Use ...
Page 82: ...4 Use Putting Out of Commission and Storage 76 1170 801 15 09 EN ...
Page 83: ...5 Maintenance ...
Page 123: ...6 Technical data ...
Page 135: ......
Page 136: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...
Page 138: ......
Page 139: ...7 Diagrams ...
Page 146: ...7 Diagrams Electrical installation 140 1170 801 15 09 EN ...
Page 148: ...7 Diagrams Electrical installation 142 1170 801 15 09 EN ...
Page 150: ...7 Diagrams Electrical installation 144 1170 801 15 09 EN ...
Page 151: ...Diagrams 7 Electrical installation Mast tilt option EXG10 EXG12 EXG16 1170 801 15 09 EN 145 ...
Page 152: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...