Maintenance
5
Maintenance every 1000 hours
Specific mast maintenance
Checking the condition of mast mounting
and its chains
– Thoroughly clean the mast guide rails and
the chains.
– Inspect surfaces for wear and check rota-
tion of rollers.
– Inspect the chains for wear, especially
around the return pulleys.
– Check the chain fixings and anchorings.
– Replace any worn chains, or any chain that
is stretched by 3 %.
– Inspect the fixing elements between the
mast and the chassis.
– Inspect the fixing collars of the mast cylin-
ders.
Adjusting the length of the mast chains
NOTE
Depending on the use of the truck, the chains
are liable to stretch and as a result they have
to be adjusted regularly.
– Lower the mast completely.
– Undo the lock nut (2).
– Place the chains under slight tension by
tightening the nut (1).
– Retighten the lock nut (2).
CAUTION
Deterioration or destruction of the equipment.
After this adjustment, check that the lift carriage
does not reach the mechanical stop at the top of
the mast. If this is the case, slacken or change the
chains. We advise you to entrust this operation to a
specialist within our network.
Cleaning and lubricating the chains
NOTE
If the lifting chain is too dirty, clean it.
– Place a recipient underneath the elevator.
1170 801 15 09 [EN]
107
Summary of Contents for EXG-10
Page 2: ......
Page 7: ...1 Introduction ...
Page 20: ...1 Introduction Environmental considerations 14 1170 801 15 09 EN ...
Page 21: ...2 Safety ...
Page 31: ...3 Overviews ...
Page 39: ...4 Use ...
Page 82: ...4 Use Putting Out of Commission and Storage 76 1170 801 15 09 EN ...
Page 83: ...5 Maintenance ...
Page 123: ...6 Technical data ...
Page 135: ......
Page 136: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...
Page 138: ......
Page 139: ...7 Diagrams ...
Page 146: ...7 Diagrams Electrical installation 140 1170 801 15 09 EN ...
Page 148: ...7 Diagrams Electrical installation 142 1170 801 15 09 EN ...
Page 150: ...7 Diagrams Electrical installation 144 1170 801 15 09 EN ...
Page 151: ...Diagrams 7 Electrical installation Mast tilt option EXG10 EXG12 EXG16 1170 801 15 09 EN 145 ...
Page 152: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...