5
Maintenance
Maintenance every 1000 hours
Electrical equipment, checking condition
of battery cables, terminals and connec-
tors
– Check that the cable insulation is undam-
aged and that there are no signs of over-
heating at the connections.
– Check that the + and - output terminals are
not sulphated (presence of white salt).
– Check the condition of the power connector
contacts and the presence of the keying pin.
CAUTION
Deterioration or destruction of the equipment
Always replace any damaged battery connector
or there is a risk that electronic components may
be damaged. Always use male and female battery
connectors of the same brand.
CAUTION
Deterioration or destruction of the equipment
The points mentioned above can cause serious
incidents. Request assistance from our service
engineers as quickly as possible.
Electromagnetic brake, checking the
brake assistance circuit for leaks
– Inspect the brake assistance hydraulic
circuit: hose and connections.
– If necessary, tighten the unions (1) of the
hose (2):
• tightening torque: 40 Nm
• on the pump unit: 35 Nm.
– Wipe away any traces of oil before they
reach the brake disc pads.
In the event of leakage, stop the truck and
contact the service engineer.
102
1170 801 15 09 [EN]
Summary of Contents for EXG-10
Page 2: ......
Page 7: ...1 Introduction ...
Page 20: ...1 Introduction Environmental considerations 14 1170 801 15 09 EN ...
Page 21: ...2 Safety ...
Page 31: ...3 Overviews ...
Page 39: ...4 Use ...
Page 82: ...4 Use Putting Out of Commission and Storage 76 1170 801 15 09 EN ...
Page 83: ...5 Maintenance ...
Page 123: ...6 Technical data ...
Page 135: ......
Page 136: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...
Page 138: ......
Page 139: ...7 Diagrams ...
Page 146: ...7 Diagrams Electrical installation 140 1170 801 15 09 EN ...
Page 148: ...7 Diagrams Electrical installation 142 1170 801 15 09 EN ...
Page 150: ...7 Diagrams Electrical installation 144 1170 801 15 09 EN ...
Page 151: ...Diagrams 7 Electrical installation Mast tilt option EXG10 EXG12 EXG16 1170 801 15 09 EN 145 ...
Page 152: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 1170 801 15 09 EN ...