Instruction Manual
151
•
Pkts 158 to 255 Octets:
The number of frames (including bad packets)
received and transmitted that were between 158 to 255 octets.
•
Pkts 256 to 511 Octets:
The number of frames (including bad packets)
received and transmitted that were between 256 to 511 octets.
•
Pkts 512 to 1023 Octets:
The number of frames (including bad packets)
received and transmitted that were between 512 to 1023 octets.
•
Pkts 1024 to 1518 Octets:
The number of frames (including bad packets)
received and transmitted that were between 1024 to 1518 octets.
•
Sample Interval:
The sample interval between 1 - 2147483647.
•
Sample Type:
The sample method used for calculating the value that is
compared against the threshold value.
•
Absolute:
Uses the absolute sample value.
•
Delta:
Uses the difference between sample values.
•
Rising Threshold:
The rising threshold value 0 - 2147483647.
•
Falling Threshold:
The falling threshold value 0 - 2147483647.
•
Rising Event:
The event that is activated when the rising threshold value is
reached.
•
Falling Event:
The event that is activated when the falling threshold value
is reached.
•
Owner:
The owner of the RMON alarm.
3.
Click on the
Apply
button to either add a new alarm or modify an existing
alarm.
Viewing RMON Alarm Information
•
On the
RMON Alarm
page, the following information will be displayed:
•
Index:
Displays the index of the alarm control entry
•
Sample Port:
Displays the current sample port.
•
Sample Variable:
Displays the current sample variable.
•
Sample Interval:
Displays the current sample interval.
•
Sample Type:
Displays the current sample alarm.
•
Rising Threshold:
Displays the rising threshold value.
•
Falling Threshold:
Displays the falling threshold value.