Instruction Manual
152
•
Rising Event:
Display the rising event that is activated once the rising
threshold is met.
•
Falling Event:
Display the falling event that is activated once the falling
threshold is met.
•
Owner:
Displays the owner of the RMON Alarm entry.
Deleting an RMON Alarm Entry
•
On the
RMON Alarm
page, click on the
Delete
button to delete the current
RMON alarm entry.
Creaitng a New RMON History or
Modifying an Existing RMON History
1.
On the
RMON History
page, select a history option from the drop-down list:
•
Create New
•
Modify Existing
2.
Enter the following information in the corresponding fields:
•
Index:
Enter a RMON history value ranging from 1 - 65535.
•
Sample Port:
Select the port that the RMON history entry will apply to from
the drop-down list.
•
Bucket Requested:
Indicate the maximum number of entries that can be
stored in RMON history. The range is 1 - 50, the default value is 50.
•
Intervals:
Indicate the RMON history sampling interval in seconds. The
range is 1 - 3600, the default value is 1800 seconds.
•
Owner:
The owner for the RMON history entry.
3.
Click on the
Apply
button to either add a new history entry or modify an
existing history entry.
Viewing RMON History
•
On the
RMON History
page, the following information will be displayed:
•
Index:
Displays the index selected for the RMON history entry.
•
Data Source:
Displays the current data source.
•
Bucket Requested:
Displays the current bucket value.
•
Interval:
Displays the current interval value.