This field allows user to set which action will be applied if the PD
is without any response. The PoE Switch Series offers the following 3 actions:
•
PD Reboot
: It means the system will reset the PoE port that is connected to the
PD.
•
PD Reboot & Alarm
: It means the system will reset the PoE port and issue an
alarm message via Syslog.
•
Alarm
: It means the system will issue an alarm message via Syslog.
6. Enter a
Reboot Time (30 - 180s).
This field allows a user to set the PoE device
rebooting time as there are so many kinds of PoE devices on the market and they
have a different rebooting time.
7. Click on the
Apply
button.
Viewing changes to the PD Alive-Check
1.
On the PD Alive Check Configuration page, the following information will be
displayed:
•
Port:
The number of the port.
•
Mode:
Displays
whether the PD Alive Check function is enabled or disabled on a
per-port basis. By default, all ports are disabled.
•
Ping PD IP Address:
Displays the PoE device IP address.
•
Click the
Edit
button to manually edit the IP address.
•
Internal Time: Displays how long system should issue a ping request to PD
for detecting whether PD is alive or dead.
•
Retry Count: Displays the number of times system retries ping to PD.
•
Action:
Displays which action will be applied if the PD is without any
response
•
Reboot Time: Displays the PoE device rebooting time as there are so many
kinds of PoE devices on the market and they have a different rebooting time.