Instruction Manual
150
Creaitng a New RMON Alarm or Modifying
an Existing RMON Alarm
1.
On the
RMON Alarm
page, select an alarm option from the drop-down list:
•
Create New
•
Modify Existing
2.
Enter the following information in the corresponding fields:
•
Index:
Enter an index value ranging from 1 - 65535.
•
Sample Port:
Select the port that the RMON Alarm will apply to from the
drop-down list.
•
Sample Variable:
Select a variable to sample:
•
Drop Events:
The number of RMON events where packets were dropped
due to a lack of resources.
•
Octets:
The number of received and transmitted bytes, includes FCS and
excludes framing.
•
Pkts:
The number of frames received and transmitted.
•
Broadcast Pkts:
The number of good frames received by the broadcast
address, does not include multicast packets.
•
Multicast Pkts:
The number of good frames received by the multicast
address.
•
CRC Align Errors:
The number of CRC/alignment errors.
•
Under Size Pkts:
The number of frames received that were less than 64
octets (excluding framing bits but including FCS octets).
•
Over Size Pkts:
The number of frames received that were longer than
1518 octets (excluding framing bits but including FCS octets).
•
Fragments:
The number of frames received that were less than 64 octets
and had either an FCS or alignment issue.
•
Jabbers:
The number of frames received that were longer than 1518
octets and had either an FCS or alignment issue.
•
Collisions:
The number of collisions on the Ethernet segment.
•
Pkts 64 Octets:
The number of frames (including bad packets) received
and transmitted that were 64 octets in length.