STACK ST8302 and ST8360 Video-Logger System
Chapter 3. Configuration
User Guide
39
Low Oil Pressure
The oil pressure below which the ‘Low Oil Pressure’ alarm is triggered.
This test can be turned on and off by setting the ON/OFF flag.
Low Battery Voltage
The battery voltage below which the ‘Low Batt’ alarm is triggered. This
test can be turned on and off by setting the ON/OFF flag.
Zero Lateral G
When installed, the V/VS Module may be positioned slightly out of
alignment (see Chapter 4 – Installation). With the vehicle on a flat
surface, the tank full of petrol and the driver at the wheel, press either
DEC or INC on the Video Controller to store the offset.
The figures displayed in this menu item will always be real-time
values from the internal channel and not the value stored.
Zero Longitudinal G
See the description for Lateral G above.
EDIT TEST
Low Oil P
35 on
EDIT TEST
Low Batt 10.0 on
EDIT OFFSET
Zero Lat G 0.00
EDIT OFFSET
Zero Long G 0.00