Chapter 3. Configuration
STACK ST8302 and ST8360 Video-Logger System
36
User Guide
Gate RPM
Specifies the engine speed above which peak values are updated. The
engine speed must exceed this value for
at least one second
in order for
the update to occur.
Switching off the Gate RPM test will disable ALL alarms. To
disable the Gate RPM test only, set it to a small value.
Start RPM
Specifies the engine speed at which the recorder will start recording
automatically (which it can only do with a LAN-C port). This should be
turned ON for LAN-C recorders and OFF for other types of recorder.
Automatic Stop
When turned on, this setting will stop the recorder when engine and
wheel speeds are zero. This option is only available when the recorder
has a LAN-C port.
Note that the Wheel Speed must have remained below ‘Peaks’ (see ‘Peaks
Speed’ setting below) for 5 seconds before the recorder switches off.
EDIT TEST
Start RPM
3000 on
EDIT TEST
Automatic Stop on
EDIT TEST
Gate RPM
3000 on