Reset and clock control (RCC)
RM0453
288/1454
RM0453 Rev 2
A switch from one clock source to another occurs only if the target clock source is ready
(clock stable after startup delay or PLL locked). If a clock source that is not yet ready is
selected, the switch occurs when the clock source becomes ready. Status bits in the
internal clock sources calibration register (RCC_ICSCR)
indicate which clock(s) is (are)
ready and which clock is currently used as a system clock.
When waking up from Standby mode, the MSI at 4 MHz is selected as system clock.
In range 2, the system clock must not exceed 16 MHz.
7.2.9
Clock source frequency versus voltage scaling
The following table gives the different clock source frequencies depending on the product
voltage range.
7.2.10 Clock
security
system on HSE32 (CSS)
The clock security system can be activated by software. In this case, the clock detector is
enabled after the HSE32 oscillator startup delay, and disabled when this oscillator is
stopped.
If a failure is detected on the HSE32 clock, the HSE32 oscillator is automatically disabled. A
clock failure event is sent to the break input of the advanced-control timers (TIM1 and
TIM16/17) and a HSE32 CSS interrupt is generated to inform the software about the failure,
allowing the MCU to perform rescue operations. The HSE32 CSS interrupt is linked to the
CPU1 and CPU2 NMI (non-maskable interrupt) exception vector.
Note:
Once the HSE32 CSS is enabled and if the HSE32 clock fails, the
HSE32 CSS interrupt
occurs and a NMI is automatically generated. The NMI is executed indefinitely unless the
CSSF
pending bit is cleared. As a consequence, in the NMI ISR (interrupt service routine),
the user must clear the
HSE CSS interrupt
by setting the
CSSC
bit in the
interrupt clear register (RCC_CICR)
.
If the HSE32 oscillator is used directly or indirectly as the system clock (indirectly meaning
HSE32 is used as PLL input clock and the PLL clock is used as system clock), a detected
failure causes a switch of the system clock to the MSI or the HSI16 oscillator depending on
the STOPWUCK configuration in the
RCC clock configuration register (RCC_CFGR)
, and
the disabling of the HSE32 oscillator. If the HSE32 clock (divided or not) is the clock entry of
the PLL used as system clock when the failure occurs, the PLL is disabled too.
Table 58. Clock source frequency
Product voltage
range
Clock frequency
MSI
HSI16
HSE32
PLL
Range 1
48 MHz
16 MHz
32 MHz
PLLRCLK = PLLQCLK = 48 MHz
PLLPCLK = 62 MHz
(VCO max = 344 MHz)
Range 2
16 MHz
16 MHz
32 MHz
(1)
1. The HSEPRE must be set to divide by two.
PLLRCLK = PLLQCLK = 16 MHz
PLLPCLK = 21 MHz
(VCO max = 128 MHz)