RM0453 Rev 2
201/1454
RM0453
Sub-GHz radio (SUBGHZ)
217
Clr_Error() command
Clr_Error(0x00)
clears all recorded sub-GHz radio errors, as reported in
Get_Error()
(RC64KCalibrationError, RC13MCalibrationError, PllCalibrationError, AdcCalibrationError,
ImageCalibrationError, XscoStartError, PllLockError and PaRampError).
5.8.8 Set_TcxoMode
command
Set_TcxoMode(RegTcxoTrim,Timeout)
is used to configure the TCXO and HSE32
ready timeout.
byte 0
bits 7:0
Opcode
: 0x17
byte 1
bits 7:0
Status[7:0]
bytes 3:2
bits 15:9 Reserved, must be kept at reset value.
bit 8
OpError_PaRampError
: PA ramping failed
bit 7 Reserved, must be kept at reset value.
bit 6
OpError_PllLockError
: RF-PLL locking failed
bit 5
OpError_XoscStartError
: HSE32 clock startup failed
bit 4
OpError_ImageCalibrationError
: Image calibration failed
bit 3
OpError_AdcCalibrationError
: RF-ADC calibration failed
bit 2
OpError_PllCalibrationError
: RF-PLL calibration failed
bit 1
OpError_RC13MCalibrationError
: Sub-GHz radio RC 13 MHz oscillator
calibration failed
bit 0
OpError_RC64KCalibrationError
: Sub-GHz radio RC 64 kHz oscillator
calibration failed
0
1
Opcode
0x00
w
w
byte 0
bits 7:0
Opcode
: 0x07
byte 1
bits 7:0 0x00
Table 39. Command format Set_TcxoMode()
Byte 0
Byte 1
Byte 2-4
Opcode = 0x97
RegTcxoTrim[2:0]
Timeout[23:0]