Shock pulse measurement
The following pages show measuring points and
possible adapter or transducer installations. How to
install measuring equipment is described in the SPM
installation manual.
Through hole for long adapter
A measuring point beneath a fan cover (1) can be reached
with a long adapter, through a hole in the cover.
Adapter with lock nut
The fan cover is fastened directly to the motor shield,
which is also the bearing housing (2). One of the cover’s
holding screws can be replaced by an adapter with lock
nut.
Bearing housings beneath brackets
Consult machine drawings and identify the bearing
housing before selecting a measuring point.
In a pump, the bearings can be placed in two separate
housings inside the bearing bracket (3).
Measuring point
B
, placed below and opposite to the
pump outlet (because of the load direction) can be
reached with a long adapter through an opening in the
pump shield.
The bearing pair at measuring point
A
can be reached
with a long adapter through a clearance hole in the
bracket. The hole must be large enough to allow bearing
adjustment and still prevent metallic contact between
bracket and adapter.
Examples of SPM measuring points
2
B
1
3
A
Summary of Contents for leonova emerald
Page 1: ...User guide PORTABLE EFFICIENCY ...
Page 2: ......
Page 6: ...A 2 General instrument functions A ...
Page 36: ...B 2 General measurement functions B ...
Page 74: ...C 2 Measurement techniques always included B C ...
Page 88: ...D D 2 Shock pulse measurement ...
Page 122: ...D D 36 Shock pulse measurement ...
Page 124: ...E E 2 Vibration measurement ...
Page 150: ...E E 28 Vibration measurement ...
Page 152: ...F F 2 Rotor balancing ...
Page 170: ...F F 20 Rotor balancing ...