General measurement functions
B:13
B
Measuring rounds for CondID
CondID is a contact free memory tag used for
measuring point recognition. It is hung on the
adapter cap or strapped in a suitable place on the
machine. It should not be mounted flat against a
metal surface. A distance of min. 3 mm between
metal surfaces and CondID
is recommended. The
tag responds to a recognition signal when Leonova
is held close to the tag.
To connect a CondID tag to measuring point, select
the measuring point in the round, press MENU and
select ’Connect CondID to measuring point’ (1).
In a downloaded measuring round, the measuring
points linked to CondID tags will be marked with a
memory tag symbol (2).
After opening the round, hold Leonova close to the
memory tag, press the MENU key and select ‘Read
CondID’ (3).
The information on the tag will open the right
measuring point in the round and Leonova is ready
for measurement.
To break the link, press MENU and select ‘Dis-
connect CondID from measuring point’ (4). Press
‘Yes’ to confirm.
When standing in a measuring round and reading
a CondID that does not belong to the round but
to the database, the instrument asks if the meas-
uring point should be added to the round so it
can be measured (5). If ‘YES’, the measuring point
will be temporary added to the round. When up-
loading the round to Condmaster, the results are
transferred but the measuring point is not added
to the measuring round.
NOTE: This functionality requires that the ‘
Down-
load all round data’
is enabled under
Data trans-
fer > Settings
in Condmaster.
3
1
2
4
5
Summary of Contents for leonova emerald
Page 1: ...User guide PORTABLE EFFICIENCY ...
Page 2: ......
Page 6: ...A 2 General instrument functions A ...
Page 36: ...B 2 General measurement functions B ...
Page 74: ...C 2 Measurement techniques always included B C ...
Page 88: ...D D 2 Shock pulse measurement ...
Page 122: ...D D 36 Shock pulse measurement ...
Page 124: ...E E 2 Vibration measurement ...
Page 150: ...E E 28 Vibration measurement ...
Page 152: ...F F 2 Rotor balancing ...
Page 170: ...F F 20 Rotor balancing ...