Spectralink 84-Series Series Wireless Telephones Administration Guide
1725-86984-000_P.docx
September 2016
269
Application <file name> is not compatible with this handset!
When the Updater displays the error ‘The application is not compatible’, an application file was
downloaded from the provisioning server but cannot be installed on this handset. This issue can
usually be resolved by finding a software image that is compatible with the hardware or the
BootROM and installing it on the provisioning server. Be aware that there are various different
hardware and software dependencies.
Do other 84-Series handsets work with this version of software?
Updater has an incorrect signature
An error is detected by a .ld file just loaded to the handset. While customers load and run
General Availability (GA) code from the Spectralink.com web site, there are a few special
84-Series handsets which use special engineering code. This error means the wrong code (GA
code on engineering handset or vice versa) is being loaded on the handset. Ensure the correct
*.sip.ld code is loaded to the handset. Download the latest code from the
web site to get GA code.
Could not contact boot server using existing configuration
The handset could not contact the provisioning server, but the causes may be numerous. It may
be related to DHCP configuration, or it could be a problem with the provisioning server itself.
The handset can recover from this error so long as it previously downloaded a valid application
BootROM image and all of the necessary configuration files.
Check the provisioning boot server IP address known by the handset at Settings
>
Status
>
Platform
>
Configuration. This screen shows Boot server IP and protocol.
Determine if the boot server IP address can be Pinged from the handset by going to
Settings
>
Status
>
Diagnostics
>
Network
>
Ping. Enter the IP address and press start.
Check the Boot server in the load protocol log file to see if there are any errors or
reasons why the configuration files do not load.
Ensure there are no network fire walls blocking the 84-Series handset from accessing
the boot server.
Error, application is not present!
This message indicates that the handset has no application (operating handset code) stored in
firmware or memory, that the handset could not download an application, and that the handset
cannot boot. To resolve this issue, you must download compatible Spectralink Software to the
handset using one of the supported provisioning protocols. You need to resolve the issue of
connecting the handset to the provisioning server and provide a compatible software image on
the provisioning server. This error is fatal, but recoverable. Check the following:
Check the boot server IP address at
Settings> Status> Platform> Configuration
.
Ensure the boot server is operational and available.