![SpectraLink 8440 Administration Manual Download Page 152](http://html.mh-extra.com/html/spectralink/8440/8440_administration-manual_1343808152.webp)
Spectralink 84-Series Series Wireless Telephones Administration Guide
1725-86984-000_P.docx
September 2016
152
The Alarm event notifies an application that a (personal security) alarm condition has been
detected or cleared on the handset.
Use the following format when viewing the alarm event:
<PolycomIPPhone
>
<AlarmNotificationEvent
>
<PhoneIP
>
172.29.71.157</PhoneIP
>
<MACAddress
>
00907a0e4459</MACAddress
>
<BSSID
>
0023ebe4ebaf</BSSID
>
<StillAlarm
>
0</StillAlarm
>
<TiltAlarm
>
1</TiltAlarm
>
<RunningAlarm
>
0</RunningAlarm
>
<DuressAlarm
>
0</DuressAlarm
>
<TimeStamp
>
2012-12-10T08:11:25-07:00</TimeStamp
>
</AlarmNotificationEvent
>
</PolycomIPPhone
>
Where
Phone IP
is the IP address of the handset
MAC Address
is the MAC address of the handset
BSSID
is the MAC address of the AP the handset is currently using
StillAlarm
is the current state of this alarm detector 0 = no alarm, 1 = alarm
TiltAlarm
is the current state of this alarm detector 0 = no alarm, 1 = alarm
RunningAlarm
is the current state of this alarm detector 0 = no alarm, 1 = alarm
DuressAlarm
is the current state of this alarm detector 0 = no alarm, 1 = alarm
TimeStamp
is the recorded time of the event
Configuration Template
The PersonalAlarm.cfg template is provided with the software download in the Config
>
Features
folder. Use it to as a starting point to customize your deployment of this feature.