36
(GB)
Symptom
The Remote Commander does not
work.
The wireless Remote Commander
does not function.
INPUT A cannot be selected.
The COVER FAIL indicator lights.
The LAMP FAIL indicator lights.
The FAN indicator lights.
The HIGH TEMP indicator lights.
When you press the ZOOM, SHIFT
or FOCUS key, “LENS CONTROL
is locked! Do you wish to unlock ?”
appears.
Cause
The batteries are exhausted.
The remote commander cable is
connected to the Remote Commander
although you are using it as a wireless
Remote Commander.
The fluorescent lamp influences on the
Remote Commander detector.
You have selected a wrong index
number.
You have set the index number to “00”.
The SIRCS RECEIVER setting is not
correct.
The switcher is not connected, but is
recognized to be connected.
The lamp cover or air filter cover is
detached.
The lamp with the same number of the
indicator has reached the end of its
life.
The fan is broken.
The internal temperature is unusually
high.
The lens control function is locked.
Remedy
Replace the batteries with new ones
(see
page 14 (GB)).
Disconnect the remote control cable.
Change the setting of SIRCS RECEIVER in
the SET SETTING menu
(see page 26 (GB)).
Select the correct index number
(see pages 26
(GB) and 31 (GB)).
Select the correct index number
(see pages 26
(GB) and 31 (GB)).
Change the setting of SIRCS RECEIVER in
the SET SETTING menu
(see page 26 (GB)).
If the PJ COM connector is connected to
something other than the terminator, remove it
then press the SYS SET key, or LIGHT and
RESET keys on the control panel.
Attach the lamp cover or air filter cover
securely
(see pages 33 (GB) and 34 (GB)).
Replace the lamp
(see page 33 (GB)).
Consult with qualified Sony personnel.
Check to see if nothing is blocking the
ventilation holes.
Consult with qualified Sony service personnel.
Caution messages
Use the list below to check the meaning of the messages displayed on the
screen.
Message
High Temperature!
Power off in 1 min.
Frequency is out of range!
Please check INPUT-A in SIGNAL
SELECT.
Please check INPUT-B in SIGNAL
SELECT.
Please check INPUT-C in SIGNAL
SELECT.
Meaning
Internal temperature becomes too high.
The frequency of the input signal is out of
the acceptable range.
You have input the RGB signal from the
computer when INPUT-A in the SIGNAL
SELECT menu is set to COMPONENT,
DTV-GBR or DTV-YP
B
P
R
.
You have input the RGB signal from the
computer when INPUT-B in the SIGNAL
SELECT menu is set to COMPONENT,
VIDEO, S-VIDEO, DTV-GBR or DTV-
YP
B
P
R
.
You have input the RGB signal from the
computer when INPUT-C in the SIGNAL
SELECT menu is set to COMPONENT,
VIDEO, S-VIDEO, DTV-GBR or DTV-
YP
B
P
R
.
Remedy
Turn off the power. (If not, the power is
automatically turned off about one minute later.)
Check to see if nothing is blocking the ventilation
holes.
Input a signal that is within the range of the
frequency.
Set INPUT-A correctly.
Set INPUT-B correctly.
Set INPUT-C correctly.
Troubleshooting
Summary of Contents for VPL-FE100E
Page 41: ...41 GB ...
Page 81: ...41 FR ...