Code
Description
Error remedy method
Refer to section
02-1A0
Optical block assembly
Ch-1B is recording data with
the maximum laser output.
(On side 0)
1.
Eject a cartridge.
2.
Check laser parameter 1 of hours meter.
When laser parameter 1 of hours meter has:
• not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-1).
• reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-1) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-1).
“3-1. Periodic Inspection”
“4-30. Main Base Assembly”
“5. Adjustment of Optical Drive
System”
02-1A5
Optical block assembly
Ch-1B detected a laser out-
put error. (On side 0)
1.
Eject a cartridge.
2.
Check laser parameter 1 of hours meter.
When laser parameter 1 of hours meter has:
• not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-1).
• reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-1) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-1).
“3-1. Periodic Inspection”
“4-30. Main Base Assembly”
“5. Adjustment of Optical Drive
System”
02-1A7
Laser drive overcurrent was
detected in optical block as-
sembly Ch-1B. (On side 0)
1.
Eject a cartridge.
2.
Check laser parameter 1 of hours meter.
When laser parameter 1 of hours meter has:
• not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-1).
• reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-1) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-1).
“3-1. Periodic Inspection”
“4-30. Main Base Assembly”
“5. Adjustment of Optical Drive
System”
02-820
Data was played with the
maximum laser output in op-
tical block assembly Ch-0A.
(On side 0)
1.
Eject a cartridge.
2.
Check laser parameter 0 of hours meter.
When laser parameter 0 of hours meter has:
• not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-0).
• reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-0) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-0).
“3-1. Periodic Inspection”
“4-30. Main Base Assembly”
“5. Adjustment of Optical Drive
System”
02-8A0
Data was played with the
maximum laser output in op-
tical block assembly Ch-0B.
(On side 0)
1.
Eject a cartridge.
2.
Check laser parameter 0 of hours meter.
When laser parameter 0 of hours meter has:
• not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-0).
• reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-0) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-0).
“3-1. Periodic Inspection”
“4-30. Main Base Assembly”
“5. Adjustment of Optical Drive
System”
Continued
ODS-D280U/ODS-D280F
2-17
Summary of Contents for ODS-D280F
Page 4: ......
Page 9: ...Frame Wiring 10 3 Revision History ODS D280U ODS D280F 5 ...
Page 10: ......
Page 12: ......
Page 158: ......
Page 238: ......
Page 248: ...Possible cause A cartridge is remaining in the unit ODS D280U ODS D280F 6 4 ...
Page 274: ......
Page 278: ......
Page 300: ......
Page 304: ......
Page 306: ......
Page 307: ......