6-7-3.
UPLOAD TO DR (MAIN)
This menu is used to update the FLASH ROM on the DR-683 board (main base assembly) with the FLASH data on the
BF-92 board (ODS-D280F) or BI-353 board (ODS-D280U).
Note
Use this menu only when the main base assembly has been replaced.
Be sure to execute this menu after the main base assembly has been replaced. Otherwise, the serial number data of the
unit is not transferred, which may prevent the unit from operating correctly.
Menu hierarchy
[OTHERS]
[MEMORY SUPPORT]
[UPLOAD TO DR (MAIN)]
Procedure
1.
Select the “UPLOAD TO DR (MAIN)” and the click the [RIGHT] button.
A confirmation window appears waiting for entry of the [SET] button.
UPLOAD TO DR (MAIN)
ARE YOU SURE?
OK: SET KEY
EXIT: MENU KEY
2.
Click the [SET] button.
The result is displayed.
LOADING...COMPLETED
EXIT: MENU KEY
OK: SET KEY
UPLOAD TO DR (MAIN)
The following information is displayed when the operation fails.
LOADING...FAILURE
EXIT: MENU KEY
OK: SET KEY
UPLOAD TO DR (MAIN)
The BF-92 board (ODS-D280F), the BI-353 board (ODS-D280U) or the DR-683 board (main base assembly) may be
defective.
ODS-D280U/ODS-D280F
6-24