6-66
HVR-M10C/M10E/M10J/M10N/M10P/M10U
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before
adjustments”
2
0
01
01
Set the data.
3
0
10
00
Set the data.
4
3
1D
Check that the data is “20”.
5
3
01
40
Set the data, and press PAUSE
button.
6
3
02
Check that the data changes
from “40” to “00”.
7
3
03
Check that the data is “00”.
(Note2)
8
Perform “Processing after
Completing Adjustments”
Note2:
If the data is other than “00”, Error rate is abnormal.
For the contents of the abnormality, see the following table.
Note3:
If Error rate is abnormal, Check the use tape, clean the tape running
surface. And after inputting initial values to page 1C: address: B3
to C8, perform re-adjustment. (See Table 6-2-16.)
Initial Value of Page 1C: Address: B3 to C8
Table 6-2-16.
Note4:
When writing the 1C page data, select page: 0, address: 10, and
set data: 01, then select C page.
After writing the initial values, reset the data of page: 0, address:
10 to “00”.
3-3. Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
01
Set the data.
3
C
0D
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
5
0
10
00
Set the data.
6
Set REC FORMAT (IN/OUT
menu) to “HDV1080i”.
3. Error Rate Check
3-1. Preparations before adjustments
Mode
Recording
Signal
Arbitrary
Switch setting:
REC FORMAT (IN/OUT menu) .............................................. DV
Adjusting method:
Order Page Address Data
Procedure
1
Set REC FORMAT (IN/OUT
menu) to “DV”.
2
0
01
01
Set the data.
3
0
10
01
Set the data.
4
C
0D
CC
Set the data, and press PAUSE
button.
5
0
10
00
Set the data.
6
Record the camera signal for
two minutes.
3-2. Error Rate Check
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
1C (Note1)
Adjustment Address
B3 to C8
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Note1:
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Data of page: 3,
address: 03
01
02
03
Contents of the abnormality
EVEN ch is abnormal.
ODD ch is abnormal.
EVEN ch and ODD ch are abnormal.
Address
B3
B4
B5
B6
B7
B8
B9
BA
Initial
value
00
00
00
00
00
80
00
00
Address
BB
BC
BD
BE
BF
C0
C1
C2
Initial
value
00
00
00
00
00
00
00
00
Address
C3
C4
C5
C6
C7
C8
Initial
value
80
00
00
00
00
00
Summary of Contents for HVR-M10C
Page 2: ... 2 HVR M10C M10E M10J M10N M10P M10U SPECIFICATIONS ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 3: ... 3 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 5: ... 5 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 13: ...1 5 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE 1 SERVICE NOTE ...
Page 14: ...1 6 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 15: ...1 7 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 16: ...1 8E HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 123: ...5 13 5 REPAIR PARTS LIST 5 REPAIR PARTS LIST HVR M10C M10E M10J M10N M10P M10U J MODEL ...
Page 328: ...ENGLISH JAPANESE ENGLISH JAPANESE ...