6-74
HVR-M10C/M10E/M10J/M10N/M10P/M10U
2-7.
LCD SYSTEM ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
NTSC model : HVR-M10J/M10U/M10N
PAL model
: HVR-M10E/M10P/M10C
Switch setting:
1)
NTSC (60i)/PAL (50i) switch (DB-018 board S201)
....... NTSC (60i)(HVR-M10J/M10U/M10N)
....... PAL (50i)(HVR-M10E/M10P/M10C)
2)
LCD panel ...................................................................... Open
3)
LCD switch ....................................................................... ON
1. LCD Automatic Adjustment (PD-222 board)
This adjustment does the following adjustment items automatically.
VCO adjustment
RGB AMP adjustment
Contrast adjustment (SD)
Mode
VTR stop, DV
Signal
Arbitrary
Adjustment Page
C
Adjustment Address
45, 46 (VCO adj.)
48 (RGB AMP adj.)
4D (Contrast adj. (SD))
-
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
If the data is “01”, adjustment has errors. Contents of the error is
written into page: 3, addresses: C6. See the following table.
Data of page: 3,
Contents of error
address: C6
53
RGB AMP adjustment error
54
Contrast adjustment (SD) error
58
VCO adjustment error
Note3:
Refer to “Table 6-3-1. Hexadecimal-decimal Conversion Table”.
Switch setting:
REC FORMAT (IN/OUT REC menu) ..................................... DV
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
Set REC FORMAT (IN/OUT
REC menu) to “DV”.
2
0
01
01
Set the data.
3
3
01
5A
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note2)
6
C
45
Read the data, and this data is
named D
45
.
7
Convert D
45
to decimal notation,
and obtain D
45
’. (Note3)
8
Calculate D
46
’ using following
equations (Decimal calculation)
When D
45
’
219
D
46
’ = D
45
’ + 36
When D
45
’ > 219
D
46
’ = 255
9
Convert D
46
’ to a hexadecimal
number, and obtain D
46
. (Note3)
10
C
46
D
46
Set the data, and press PAUSE
button.
11
0
01
00
Set the data.
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
Set REC FORMAT (IN/OUT
REC menu) to “DV”.
2
0
01
01
Set the data.
3
3
01
5A
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note2)
6
C
46
Read the data, and this data is
named D
46
.
7
Convert D
46
to decimal notation,
and obtain D
46
’. (Note3)
8
Calculate D
45
’ using following
equations (Decimal calculation)
When D
46
’
36
D
45
’ = D
45
’ – 36
When D
46
’ < 36
D
45
’ = 0
9
Convert D
45
’ to a hexadecimal
number, and obtain D
45
. (Note3)
10
C
45
D
45
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
Fig. 6-2-15.
DB-018 BOARD (SIDE A)
S201
Summary of Contents for HVR-M10C
Page 2: ... 2 HVR M10C M10E M10J M10N M10P M10U SPECIFICATIONS ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 3: ... 3 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 5: ... 5 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 13: ...1 5 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE 1 SERVICE NOTE ...
Page 14: ...1 6 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 15: ...1 7 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 16: ...1 8E HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 123: ...5 13 5 REPAIR PARTS LIST 5 REPAIR PARTS LIST HVR M10C M10E M10J M10N M10P M10U J MODEL ...
Page 328: ...ENGLISH JAPANESE ENGLISH JAPANESE ...