6-68
HVR-M10C/M10E/M10J/M10N/M10P/M10U
2. S VIDEO OUT Y Level Adjustment (VC-367 board)
Note1:
< >: NTSC(60i) mode, [ ]: PAL(50i) mode
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Y signal terminal of S VIDEO jack
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
<25> [85]
Specified Value
A = 1000
+20
mV
–8
Note2:
Disconnect the cable from the COMPONENT OUTPUT
connector.
Note3:
The data of page: 0, address: 10 must be “00”.
Switch setting:
60i/50i SEL ......................................................... <60i>, [50i]
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
02
Set the data, and press PAUSE
button.
3
Wait for 5 sec.
4
3
11
Check that bit5 of the data is
“1”. (Note4)
5
C
<25>
Change the data and set the Y
[85]
signal level (A) to the specified
value.
6
C
<25>
Press PAUSE button.
[85]
7
3
0C
00
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
Note4:
For the bit values, refer to “6-3. SERVICE MODE”, “3-3. 3. Bit
value discrimination”.
3. S VIDEO OUT Chroma Level Adjustment
(VC-367 board)
Note1:
< >: NTSC(60i) mode, [ ]: PAL(50i) mode
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
jack (75
Ω
terminated)
External trigger: Y signal terminal of
S VIDEO jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
<26, 27> [86, 87]
Specified Value
Cr level:
A = 714
±
14mV (NTSC)
A = 700
±
14mV (PAL)
Cb level:
B = 714
±
14mV (NTSC)
B = 700
±
14mV (PAL)
Burst level: C = 286
±
6mV (NTSC)
C = 300
±
6mV (PAL)
Note2:
Disconnect the cable from the COMPONENT OUTPUT
connector.
Note3:
The data of page: 0, address: 10 must be “00”.
Switch setting:
60i/50i SEL ......................................................... <60i>, [50i]
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
02
Set the data, and press PAUSE button.
3
Wait for 5 sec.
4
3
11
Check that bit5 of the data is
“1”. (Note4)
5
C
<26>
Change the data and set the Cr
[86]
signal level (A) to the specified value.
6
C
<26>
Press PAUSE button.
[86]
7
C
<27>
Change the data and set the Cb
[87]
signal level (B) to the specified value.
8
C
<27>
Press PAUSE button.
[87]
9
Check that the burst signal level
(C) is satisfied the specified value.
10
3
0C
00
Set the data, and press PAUSE button.
11
0
01
00
Set the data.
Note4:
For the bit values, refer to “6-3. SERVICE MODE”, “3-3. 3. Bit
value discrimination”.
Fig. 6-2-6.
Fig. 6-2-7.
H
A
H
C
A
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
B
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
Summary of Contents for HVR-M10C
Page 2: ... 2 HVR M10C M10E M10J M10N M10P M10U SPECIFICATIONS ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 3: ... 3 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 5: ... 5 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 13: ...1 5 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE 1 SERVICE NOTE ...
Page 14: ...1 6 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 15: ...1 7 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 16: ...1 8E HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 123: ...5 13 5 REPAIR PARTS LIST 5 REPAIR PARTS LIST HVR M10C M10E M10J M10N M10P M10U J MODEL ...
Page 328: ...ENGLISH JAPANESE ENGLISH JAPANESE ...