6-84
HVR-M10C/M10E/M10J/M10N/M10P/M10U
8. Record of Use check (1)
Page 7
Address A4 to AF
Note1:
When replacing the drum assembly or the mechanism deck, initialize the data of address: A7 to A9.
Note2:
This data will be kept even if the lithium battery (LI-073 board BT591) is removed.
Note3:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
The record of use data is displayed at addresses: A4 to AF.
Initializing method:
1)
Select page: 7, address: 01, set the following data.
70: (Initializing the power supply operation counted time.)
71: (Initializing the drum rotation counted time.)
72: (Initializing the tape running counted time.)
73: (Initializing the unloading counter.)
2)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
3)
Check that the data of page: 7, address: 02 changes to “01”.
4)
Select page: 7, address: 00, and set data: 00.
5)
Select page: 7, address: 01, and set data: 00.
Note:
HOURS METER (OTHERS menu) is also reset simultaneously.
9. Record of Use check (2)
Page 7
Address C8 to CD
Note1:
This data will be kept even if the lithium battery (LI-073 board BT591) is removed.
Note2:
The data of page: 0, address: 10 must be “00”.
Hour (H)
Hour (M)
Hour (L)
Hour (H)
Hour (M)
Hour (L)
Hour (H)
Hour (M)
Hour (L)
Hour (H)
Hour (M)
Hour (L)
Power supply operation
counted time
(BCD code)
Drum rotation
counted time
(BCD code)
Tape running
counted time
(BCD code)
Unloading counter
(BCD code)
Address
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
Function
Remarks
100000th place digit and 10000th place digit of counted time
1000th place digit and 100th place digit of counted time
10th place digit and 1st place digit of counted time
100000th place digit and 10000th place digit of counted time
1000th place digit and 100th place digit of counted time
10th place digit and 1st place digit of counted time
100000th place digit and 10000th place digit of counted time
1000th place digit and 100th place digit of counted time
10th place digit and 1st place digit of counted time
100000th place digit and 10000th place digit of counted time
1000th place digit and 100th place digit of counted time
10th place digit and 1st place digit of counted time
Using method:
1)
The record of use data is displayed at addresses: C8 to CD.
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence data
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
Summary of Contents for HVR-M10C
Page 2: ... 2 HVR M10C M10E M10J M10N M10P M10U SPECIFICATIONS ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 3: ... 3 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 5: ... 5 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 13: ...1 5 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE 1 SERVICE NOTE ...
Page 14: ...1 6 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 15: ...1 7 HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 16: ...1 8E HVR M10C M10E M10J M10N M10P M10U ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 123: ...5 13 5 REPAIR PARTS LIST 5 REPAIR PARTS LIST HVR M10C M10E M10J M10N M10P M10U J MODEL ...
Page 328: ...ENGLISH JAPANESE ENGLISH JAPANESE ...