![Sony DCR-TRV725E Service Manual Download Page 212](http://html.mh-extra.com/html/sony/dcr-trv725e/dcr-trv725e_service-manual_392537212.webp)
— 8 —
1-2-3. Mechanism Status (Position) Transition Table Using Mode Selector II
After selecting a mechanism deck, select either the MANUAL or
STEP test (not AUTO) using the Mode Selector II. The desired
mechanism status (position) can be specified by pressing the RVS
or FF button. (The selected status appears on STATUS.)
EJ
y
USE
y
LOAD
y
STOP
y
TURN
y
RP
y
REW
1-2-4. Battery Alarm Indication
When the level of the battery used to supply power to this system
decreases, this display appears asynchronously. When this happens,
all operations are disabled and the battery must be replaced.
Fig. f
MD name
Code
A
B
C
1
0
0
1
1
0
0
1
0
0
1
1
0
0
1
0
0
0
1
0
1
1
2
3
4
5
6
7
M2000 Mechanism
EJ
USE
LOAD
STOP
TURN
RP
REW
BATT DOWN
CHANGE PLEASE
[
0 is common and short.
]
1 is common and open.