11. Mechanical Shutter Data Input
Adjustment Page
4
A
Adjustment Address
1D to 20
70 to 84
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: 4, addresses: 1D to 20.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
3)
Input the following data to page: A, addresses: 70 to 84.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
4)
Select page: 0, address: 01, and set data: 00.
12. Angular Velocity Sensor Sensitivity Adjustment
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03JA
Type B: ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing, re-
adjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
A
Adjustment Address
66, 67
Specified Value
17C0 to 27C0
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
NTSC model: DCR-TRV730/TRV828/TRV830
PAL model: DCR-TRV725E/TRV730E/TRV828E/ TRV830E
Switch setting:
1)
STEADY SHOT (Menu display) ...................................... ON
2)
ZOOM .......................................................................... Center
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
A
66
Set the following data, and press
PAUSE button.
78 (NTSC), 8D (PAL)
3
A
67
Set the following data, and press
PAUSE button.
83 (NTSC), 98 (PAL)
Pitch sensor check
(SI-030 board SE301)
4
6
0B
11
Set the data.
5
1
Check that the display data (Note1)
satisfies the specified value.
Yaw sensor check
(SI-030 board SE302)
6
6
0B
12
Set the data.
7
1
Check that the display data (Note1)
satisfies the specified value.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
0B
00
Set the data.
2
0
01
00
Set the data.
3
Move the camcorder, and check
that the steady shot operations
have been performed normally
Address
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
Data
08
14
A1
0F
60
0D
8E
0B
16
0A
B3
51
DD
63
44
71
B1
72
9F
67
1D
Address
1D
1E
1F
20
Data
77
80
81
81
RadarW
RadarW