5-23
8. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
A
Adjustment Address
1E, 1F, 30 to 33
Specified Value
0FF0 to 1010
Note1:
This adjustment should be carried out upon completion of “Color
reproduction adjustments”.
Note2:
After the power is turned on, this adjustment can be done only
once.
Note3:
Check that the data of page: 6, address: 09 is “00”. If not, to page:
6, address: 08, set data: 00, and press the PAUSE button.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
A
24
Write down the data.
3
A
24
93
Set the data, and press PAUSE
button.
4
A
25
Write down the data.
5
A
25
93
Set the data, and press PAUSE
button.
6
A
26
Write down the data.
7
A
26
91
Set the data, and press PAUSE
button.
8
A
27
Write down the data.
9
A
27
8F
Set the data, and press PAUSE
button.
10
6
16
02
Set the data, and wait for 1sec.
11
6
08
11
Set the data, and press PAUSE
button.
12
6
08
0D
Set the data, and press PAUSE
button
13
6
09
Check that the data changes to
“01”. (Note5)
14
A
10
2E
Set the data, and press PAUSE
button.
15
1
Check that the display data (Note4)
satisfies the specified value.
Note5:
The adjustment data will be automatically input to page: A, address:
1E, 1F, 30 to 33.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
08
00
Set the data, and press PAUSE
button.
2
6
16
00
Set the data.
3
A
10
00
Set the data, and press PAUSE
button.
4
A
24
Set the data that is written down
at step 2, and press PAUSE button.
5
A
25
Set the data that is written down
at step 4, and press PAUSE button.
6
A
26
Set the data that is written down
at step 6, and press PAUSE button.
7
A
27
Set the data that is written down
at step 8, and press PAUSE button.
8
0
01
00
Set the data.
RadarW
RadarW
RadarW