5-24
14. Strobe White Balance Adjustment
Adjust the white balance when the strobe light flashed.
Mode
STILL
Subject
Flash adjustment box (Note 3)
(1.0 m from the front of lens)
Adjustment Page
F
Adjustment Address
4D, 4E, 64, 69, 6A, 6B
Specified Value
Y level data: 64 to 98 (Note 4)
R-Y level data: FA to FF or 00 to 06
(Note 5)
B-Y level data: FA to FF or 00 to 06
(Note 5)
A/D integral value data: 0020 or
more (Note 6)
Note 1:
Perform “Flange Back Adjustment”, “Light Level
Adjustment” and “Auto White Balance Adjustment”
before this adjustment.
Note 2:
Perform this adjustment in the Flash adjustment box.
Note 3:
Refer to “4. Preparing the Flash adjustment box”. (See
page 5-7)
Note 4:
Displayed data of page: F, address: 64, of the adjusting
remote commander.
F:XX:64
Displayed data
Note 5:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
R-Y level data
B-Y level data
Note 6:
Displayed data of page: F, address: 69, 6A of the adjusting
remote commander.
F:XX:69
Displayed data
F:XX:6A
Displayed data
XX XX
Page: F, address: 6A (Lower)
Page: F, address: 69 (Higher)
Note 7:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting:
1) FLASH ........................ ON
Checking method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
Perform “Data setting during
4
camera system adjustment”.
(Refer to page 5-13)
5
6
90
00
6
6
91
00
7
6
92
00
8
6
93
60
9
6
6C
01
10
6
2C
01
11
6
01
79
Press PAUSE button.
12
7
01
44
Press PAUSE button.
13
Wait for 5 seconds.
Order Page Address Data
Procedure
14
6
01
67
Press PAUSE button.
15
6
02
Check the data changes to
“01”.
16
6
01
00
Press PAUSE button.
17
6
01
79
Press PAUSE button.
18
Wait for 1 second.
19
6
01
67
Press PAUSE button.
20
6
02
Check the data changes to
“01”.
21
6
01
00
Press PAUSE button.
22
6
01
79
Press PAUSE button.
23
Wait for 1 second.
24
6
01
B9
Press PAUSE button. (Note 8)
25
6
02
Check the data changes to
“01”.
26
6
01
00
Press PAUSE button.
27
6
01
79
Press PAUSE button.
28
Wait for 1 second.
29
6
01
67
PAUSE button.
30
6
02
Check the data changes to
“01”.
Check that the Y level data
31
F
64
(Note 4) satisfies the specified
value.
32
0
03
02
Check that the R-Y, B-Y level
33
1
data (Note 5) satisfies the
specified value.
69
Check that the A/D integral value
34
F
6A
data (Note 6) satisfies the
specified value.
Note 8:
The adjustment data will be automatically input to page:
F, address: 4D, 4E, 64 and 69 to 6B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
6
93
00
3
6
01
00
Press PAUSE button.
4
6
6C
00
5
7
01
04
Press PAUSE button.
6
0
03
00
7
5
F1
00
8
D
63
00
Press PAUSE button.
Release the data setting
9
performed at step 4.
(Refer to page 5-13)
10
0
01
00