5-9
3.
B Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7 Page Data”)
Address Initial value
Remark
00
Fixed data-2
01 to FF
Fixed data-1 (Initialized data)
4.
E Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7 Page Data”)
Address Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
1-2-2.
Initializing B, E, F, 7 Page Data
1.
Initializing B, E, F, 7 Page Data
Note:
If the B, E, F Page data has been initialized, “Modification
of B, E, F, 7 Page Data” and following adjustments need
to be performed again.
1) Modification of B, E, F, 7 page data
2) Video system adjustments
3) Camera system adjustments
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data Procedure
1
0
01
01
2
B
00
00
Press PAUSE button.
3
6
03
09
4
6
00
2D
5
6
01
2D
Press PAUSE button.
6
6
02
Check the data changes to “01”.
7
Perform “Modification of B,
E, F, 7 page Data”.
2.
Modification of B, E, F, 7 Page Data
If the B, E, F, 7 Page data has been initialized, change the data of
the “Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7 Page data
Order Page Address Data Procedure
1
6
00
29
2
6
01
29
Press PAUSE button.