5-16
3. Flange Back Check
Mode
STILL
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified value
Focused at the TELE end and
WIDE end
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 2.0 m
from the front of the lens.
To open the IRIS , decrease
2
the luminous intensity to the
Siemens star up to a point be-
fore noise appear on the image.
3
0
01
01
4
5
F1
FF
5
D
63
40
Press PAUSE button.
Perform “Data setting during
6
camera system adjustment”.
(Refer to page 5-13)
7
Shoot the Siemens star with
the zoom TELE end.
8
Turn on the auto focus.
9
Check that the lens is focused.
10
6
2C
01
While observe the TV monitor,
11
change the zoom to the WIDE
end and check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
5
F1
00
3
D
63
00
Press PAUSE button.
Release the data setting
4
performed at step 6.
(Refer to page 5-13)
5
0
01
00
4. F No. Standard Data Input
Compensate the unevenness of the iris meter sensitivity.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
29 to 2C
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Shoot the Clear chart with
the zoom WIDE end.
2
0
01
01
3
5
F1
FF
4
D
63
40
Press PAUSE button.
Perform “Data setting during
5
camera system adjustment”.
(Refer to page 5-13)
6
E
51
Note down the data.
7
E
51
FF
Press PAUSE button.
8
6
01
BB
Press PAUSE button.
(Note 2)
9
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 29 to 2C.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
E
51
Set data noted down at step 6,
and press PAUSE button.
3
5
F1
00
4
D
63
00
Press PAUSE button.
Release the data setting
5
performed at step 5.
(Refer to page 5-13)
6
0
01
00