5-21
10. Smear Compensation Adjustment
Adjust the smear compensation data from white balance standard
data at 3200K.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
9D, 9E
Note 1:
Perform “Auto White Balance Standard Data Input” and
“Auto White Balance Adjustment” before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
Perform “Data setting during
4
camera system adjustment”.
(Refer to page 5-13)
5
F
27
Note down the data.
6
F
27
80
Press PAUSE button.
7
6
01
11
Press PAUSE button.
8
6
13
88
Press PAUSE button.
9
6
01
D1
Press PAUSE button. (Note 3)
10
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 9D and 9E.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
F
27
Set data noted down at step 5,
and press PAUSE button.
3
6
13
00
Press PAUSE button.
4
5
F1
00
5
D
63
00
Press PAUSE button.
Release the data setting
6
performed at step 4.
(Refer to page 5-13)
7
0
01
00
11. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Mode
STILL
Subject
Color bar chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
41 to 48, 5C to 5F
Note 1:
Perform “Auto White Balance Reference Data Input”
before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
Perform “Data setting during
4
camera system adjustment”.
(Refer to page 5-13)
5
6
01
AB
Press PAUSE button.
6
6
01
A9
Press PAUSE button (Note 3)
7
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 41 to 48 and 5C to 5F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
5
F1
00
3
D
63
00
Press PAUSE button.
Release the data setting
4
performed at step 4.
(Refer to page 5-13)
5
0
01
00
6
Perform “Color Reproduction
Check”.