5-18
6. Picture Frame Setting
Mode
STILL
Subject
Color bar chart
(Color reproduction adjustment
frame)
Measurement Point
Video terminal of A/V OUT jack
(75
Ω
terminated)
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Note 1:
Displayed data of the page 1 of adjusting remote
commander.
1:XX:XX
XL or YL data
XH or YH data
Setting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
Perform “Data setting during
4
camera system adjustment”.
(Refer to page 5-13)
Adjust the zoom and the camera
5
direction, and set to the picture
frame to the specified position.
Mark the position of the picture
frame on the TV picture
monitor, and adjust the picture
6
frame to this position in
following adjustment using
“Color reproduction
adjustment frame”.
7
0
03
18
8
1
Note down the XH and XL
data. (Note 1)
9
0
03
22
10
1
Note down the YH and YL
data. (Note 1)
11
0
03
00
12
5
F1
00
13
D
63
00
Press PAUSE button.
Release the data setting
14
performed at step 4.
(Refer to page 5-13)
15
0
01
00
Check on the oscilloscope
1. Horizontal period
Fig. 5-1-14
2. Vertical period
Fig. 5-1-15
Check on the TV monitor
Fig. 5-1-16
A=B
C=D
A
B
C
D
Color bar chart picture frame
TV monitor picture frame
E=F
V
E
F
How to reset the zoom and focus when they deviated:
Order Page Address Data
Procedure
1
6
90
XL
(Note 2)
2
6
91
XH
(Note 2)
3
6
92
YL
(Note 3)
4
6
93
YH
(Note 3)
5
6
6C
01
6
6
01
79
Press PAUSE button.
7
Wait for 1 second.
8
6
2C
01
9
6
01
00
Press PAUSE button.
Note 2:
The data noted dowm at step 8 of “Setting method”.
Note 3:
The data noted dowm at step 10 of “Setting method”.