5-19
7. Light Level Adjustment
Adjust the standard LV value.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Measurement Point
Displayed data of page: 1 (Note 2)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
26, 28
Specified Value
AE level 1: 0FE0 to 1020
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
Perform “Data setting during
4
camera system adjustment”.
(Refer to page 5-13)
5
6
01
0D
Press PAUSE button. (Note 3)
6
6
02
Check the data changes to
“01”.
7
0
03
06
Check that the displayed data
8
1
(Note 2) satisfies the AE level
1 specified value.
Note 3:
The adjustment data will be automatically input to page:
F, address: 26 and 28.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
5
F1
00
4
D
63
00
Press PAUSE button.
Release the data setting
5
performed at step 4.
(Refer to page 5-13)
6
0
01
00
8. Auto White Balance Standard Data Input
Adjust the white balance standard data at 3200K.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
3A to 3D, 59
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for XH, XL, YH and
YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
Perform “Data setting during
4
camera system adjustment”.
(Refer to page 5-13)
5
6
90
00
6
6
91
04
7
6
92
00
8
6
93
30
9
6
6C
01
10
6
2C
01
11
6
01
79
Press PAUSE button.
12
Wait for 3 seconds.
13
6
01
11
Press PAUSE button.
14
6
01
0B
Press PAUSE button. (Note 3)
15
6
02
Check the data changes to
“01”.
16
6
90
XL
(Note 2)
17
6
91
XH
(Note 2)
18
6
92
YL
(Note 2)
19
6
93
YH
(Note 2)
20
6
6C
01
21
6
2C
01
22
6
01
79
Press PAUSE button.
23
Wait for 3 seconds
Note 3:
The adjustment data will be automatically input to page:
F, address: 3A to 3D and 59.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
6C
00
3
6
2C
00
4
5
F1
00
5
D
63
00
Press PAUSE button.
Release the data setting
6
performed at step 4.
(Refer to page 5-13)
7
0
01
00
8
Perform “Auto White
Balance Adjustment”.