7-68
HDW-F900R/V1 (E)
7-19. T Soft Brake Replacement
Replacement (Perform the part replacement according to the following
procedure.)
Removing the T soft brake
Installing the T soft brake
Adjustment after replacement
Capstan add-on recording adjustment
Note
If a tape hunts or slackens during the REW mode, replace the T soft brake.
Preparations
1.
Check that the unit is in the unthreading-end state.
2.
Turn off the main power.
3.
Remove the front lid and outside panel assembly. (Refer to Section 1-4.)
n
The T Soft Brake can be replaced when the cassette compartment attaches to the unit.
n
The stop washer is used to fix the T soft brake.
Prepare a new stop washer (3-559-408-11) when replacing it.
Brake spring
T soft brake
Stop washer
Tools
.
Stop washer fastening tool : J-6323-530-A
.
Cleaning cloth :
3-184-527-01
.
Cleaning fluid :
9-919-573-01
Removal
1. Removing the T soft brake
(1) Remove the extension spring from the T soft
brake.
(2) Remove the stop washer and remove the T
soft brake.