3-8
HDW-F900R/V1 (E)
E-x89
Contents :
FORMAT setting switch error
Detecting conditions : NO. 5 of the SS-92G board S101 is set to ON (forcible mode).
Suspected cause :
Initial setup at board replacement is wrong.
E-x91
Contents :
RE-TAKE error
Detecting conditions : When the cue-up operation has failed at RE-TAKE, VF shows “Retake Search
failed”.
Suspected cause :
Playback of the TIMECODE record is faulty.
E-x92
Contents :
DVP TG IC LOCK error
Detecting conditions : The DVP-41 board TG IC (IC200) cannot PLL-LOCKED.
Suspected cause :
.
GENLOCK IN signal is defective.
.
The DVP-41 board IC219, IC242 and IC243 is faulty.
E-x95
Contents :
VTR System control microprocessor abnormal
Detecting conditions : The camera block microprocessor or the microprocessor on the FP-152 board
cannot communicate with the VTR system control microprocessor.
Suspected cause :
VTR system control microprocessor has hung up. (Turn off the power and turn it
on again to recover.)
3-2. Device Check
The HDW-F900R has the self-diagnostics function to check the communication function of the respective
devices.
Result of the self-diagnostics is displayed on the [DEV STATUS display] of the DIAGNOSIS menu.
(For more details, refer to Section “4. Setup Menu”.)
Summary of Contents for CineAlta HDCAM HDW-F900R
Page 13: ...1 3 HDW F900R V1 E View of the outside panel assembly Front view ...
Page 14: ...1 4 HDW F900R V1 E 1 1 2 Locations of Main Mechanical Parts 1 2 3 4 5 6 7 8 9 0 ...
Page 108: ...2 18 HDW F900R V1 E 2 4 3 5 7 1 9 8 6 6 ...
Page 212: ......
Page 232: ......
Page 272: ......
Page 486: ......
Page 500: ......
Page 544: ......
Page 545: ......
Page 546: ...Printed in Japan Sony Corporation 2006 10 16 2006 HDW F900R SY E 9 968 281 02 ...