3-1
FVS-1000 MMP1
Perform the periodic checks and maintenance in order to ensure correct function and performance and
also to extend the life of the film.
3-1. Periodic Inspection List
The time shown below is not the warranted time of the part. Use the following time as reference to plan
the maintenance and inspection. The time for the part replacement depends on circumstances and
conditions where the system is operated.
C : Inspection and cleaning
R : Replacement
Inspection item
Inspection time (h) (Lamp lighting time)
Replaced part Amount
1000
2000
3000
4000
5000
6000
7000
8000
Part number
Lamp
R
R
R
R
R
R
R
R
1-517-872-11
1
Gate base (35) assembly
C
C
C
C
A-8321-665-
1
(Film position fixing support)
(3-616-888-)
(4)
(Film support assembly)
(A-8321-666-)
(1)
Retainer (35) assembly
C
C
C
C
A-8321-664-
1
I Sprocket 35/16
R:7500 h
R:15000 h
3-617-172-01
2
C Sprocket 35/16
R:7500 h
R:15000 h
3-617-173-01
2
Filter Assembly
R:7500 h
R:15000 h
A-8321-649-
1
IR/UV Cut Filter
R:7500 h
R:15000 h
1-758-295-11
1
LED (Analog audio)
R:15000 h
Audio drum (Upper)
R:15000 h
Audio drum (Lower)
R:15000 h
.
As for the element and mist separator (AFM2000) of the filter regulator (AW2001), it is recommended
to replace them every two years or when the pressure decreases to 0.1 MPa (1 Kgf
.
cm).
Section3
Periodic Check and Maintenance