1-13
FVS-1000 MMP1
1-10. Installation Procedure
11. Adjust the air pressure according to the following procedure.
(1) Supply the outside air.
(2) Pull up the regulator knob to release the lock.
(3) Turn the regulator knob with pushing the red button of the electromagnetic valve. Turning the
regulator knob so that the indicator of the manometer may point to the following value.
Specification : 0.1 Mpa (1 kgf/cm
2
)
(4) Release the red button of the electromagnetic valve.
Push the regulator knob to be locked.
(5) Stop supplying the outside air.
12. Install the air filter cover removed in procedure 3.
n
Be careful not to insert the harness between the air blow assembly and the air filter cover.
Electromagnetic
valve
Red button
0
1
0.2
0.8
0.4 0.6
MPa
(kgf/cm )
2
Regulator knob